The reviewed Record K200 literature distinguishes three-wing and four-wing configurations. Its current retrieved user manual identifies K200-3-5 and K200-4-5. Selection needs more than a diameter: internal and external dimensions, usable passage, night-closing doors and emergency options have separate conditions.
Identify the complete assembly before comparing proposals
The official UK product page lists three- and four-wing K200 arrangements. The retrieved user manual is article 1025566, version 2.0, dated 2026-01-27, for K200-3-5 / K200-4-5. Keep that complete identity in an enquiry, order or repair record.
Other K-series names and appearance ranges need their own documents. A model number does not establish a universal hierarchy of manual, economy and higher-capacity equipment. Existing doors need their labels and original documents; proposed equipment needs the supplier's configuration and applicable drawing.
Even two three-wing proposals can differ in glazing, construction, controls, night closing and options. An appearance rendering is not a configuration list. Keep the quotation revision connected to the drawing, equipment schedule and later delivery record.
Internal diameter is not external occupation or passage width
The K200 datasheet with a 12/2024 footer separates internal diameter D from external diameter DT. It gives different relationships for ordinary external dimensions and internal or external night-closing doors. It also distinguishes true passage width TW and folded-position dimensions by wing count and night-closing arrangement.
As a document-reading example only, D = 3000 mm gives 3096 mm under the ordinary D + 96 mm relationship. This does not establish a building opening, ground-ring allowance or project clearance. Other arrangements in the same table use different relationships.
| Object in the cited datasheet | Source distinction | Evidence still needed |
|---|---|---|
| Internal diameter D | Internal size and listed increments | Proposed assembly and drawing revision |
| Ordinary external diameter DT | D + 96 mm in the cited table | Actual construction; no conversion into a site allowance |
| Night-closing external dimension entries | D + 184 mm internal NCD; D + 224 mm external NCD | Selected closing arrangement and building interfaces |
| True passage width TW | Separate wing-count and closing-arrangement entries | Actual people, carried objects and passage requirements |
| Folded-position dimensions | Separate from ordinary revolving passage | Applicable option, state drawing and conditions |
Preserve the dimension name, reference and configuration. The relationships explain the cited source; they are not a universal construction table or a substitute for the supplied installation drawing.
Compare the movement space with the actual users
Avoid deciding from wing count alone that one proposal suits every luggage movement or another suits every traffic peak. Identify the actual users and carried objects, then examine compartments, entrance geometry, movement and operating arrangements.
The official K200 literature relates different passage needs to configuration. It does not justify a promise that every diameter suits wheelchairs, luggage or trolleys. Nor does it justify declaring every revolving door unsuitable for those users. The complete route and project requirements still need review.
Describe concentrated arrivals, simultaneous directions and the way carried objects affect movement. Do not transfer a broad capacity range into a site commitment without its conditions. Any additional passage must be considered as part of the complete entrance, not assumed adequate because a side door appears on a drawing.
Keep breakout, night closing and reception controls separate
Section 3.2 on page 18 of manual 1025566 describes emergency breakout as an option. It does not establish that every automatic revolving door unfolds after power loss. The actual assembly, locks, operating mode, supply and project interfaces need their own confirmation.
Section 4.17 on page 32 makes a specific distinction between line of sight and the role of the reception panel. In the relevant configuration without a direct view of the door, the panel is read-only. Seeing information on a display does not establish permission or suitability to change the mode remotely.
This guide supplies no panel configuration, unlocking, breakout or reset procedure. Site use, coordinated checks and emergency arrangements need the applicable equipment instructions and trained personnel. The general integration evidence guide helps separate requests and feedback but does not replace K200 documentation.
Installation needs the building interfaces as well as the door drawing
Section 3.1 identifies a pedestrian-passage purpose and dry installation conditions, with appropriate site waterproofing and drainage required for deviations. Equipment literature does not establish weather protection of an entire building interface.
Coordinate fixing, floor finish, overhead construction, cables, maintenance access and neighbouring fixtures. Identify who confirms and completes each item. Later changes to mats, finishes or furniture may affect the reviewed arrangement and should remain traceable.
Keep delivery, mechanical installation, interface coordination and the conditions for use as separate milestones. A quotation saying installation included does not define all electrical, building, management and specialist work.
Record the event before ordering a repair part
For a door that will not rotate or does not stop correctly, record the time, actual mode, complete PS-RD indication, physical behaviour and recent cleaning, construction or changes to mats and night closing. Obtain labels and photographs only from safe accessible positions.
Chapter 8 of the manual distinguishes different symptoms. Page 55 refers incorrect stopping or locking-position problems to a service technician. Motor noise does not establish a failed motor, and lack of rotation does not establish a failed control board. Do not apply another model's code table by repeated resets or trial replacement.
| Work or fault record | Relationship to retain | Answer to obtain |
|---|---|---|
| Assembly identity | Complete model, wings, closing arrangement, options and revision | Applicable diagnostic and parts documents |
| Event sequence | Time, mode, full indication, position and recent changes | Observations separated from diagnosis |
| Replacement enquiry | Equipment, old-part and proposed-part identities | Compatibility, installation and checks |
| Inspection and maintenance | Configuration, objects, use changes and personnel | Plan, results, unresolved items and follow-up |
| Return to service | Actual work, configuration, records and recipient | Conditions for use and document retention |
Manage protection faults, unintended movement and equipment needing repair under site procedures. Keep people out of hazardous movement areas and contact appropriately qualified personnel. Do not ask passers-by to test protection, touch moving parts or bypass a protective device.
Maintain the equipment documents and inspection records together with the applicable site records. A period for one component or another series does not establish the complete maintenance plan for this assembly.
Itemise the proposal and preserve the handover
Download the original K200 identity, dimensions and service worksheet (CSV). Separate known facts from unanswered conditions. Itemise the assembly, controls, glazing, finish, night closing, emergency options, activation and protection, building work, transport and site services.
The worksheet is a communication aid, not a manufacturer drawing, safety certificate or project acceptance. Supply, attendance, warranty and responsibility need the actual documents and agreement. No unverified market price, local stock or overseas service infrastructure is implied here.
For the wider entrance brief, see the Chinese hotel route and operations guide. Different door types and supply responsibilities are covered in the international enquiry guide.
Source scope and contact
Reviewed on 2026-11-02: official Record UK K200 product page; two-page Datasheet_Record_K200_en.pdf, footer 12/2024; and user manual 1025566, version 2.0, dated 2026-01-27, for K200-3-5 / K200-4-5. Selected dimension entries retain their source scope. Entries from different objects, revisions or configurations must not be merged into an unconditional specification.
Business enquiries: 河南联同创智能科技有限公司, Mr Wang, +86 13271597000. Confirmed business address: 河南省郑州市新郑市龙湖镇华南城11A1-16号. The authorisation image on the Chinese homepage states 2026-06-01 to 2026-12-31. Confirm the actual product, territory, supply and site-work scope for the enquiry; the image does not establish project suitability or overseas infrastructure.
Frequently asked questions
Is K200 a two-, three- or four-wing revolving door?
The reviewed official K200 literature lists three and four wings. The retrieved manual identifies K200-3-5 / K200-4-5. Other arrangements need their own documents rather than combining the entire K-series range under K200.
Does a three-metre internal diameter define the building opening?
No. Internal diameter, external occupation, night closing and passage dimensions are different objects. Building allowances, floor and fixing need the actual installation drawing and responsible review.
Do three and four wings give identical passage at the same diameter?
Do not assume so. The source separates wing count and night-closing arrangements in its passage and folded-position entries. Review the actual use with the corresponding drawing.
Does every K200 have breakout and automatic unfolding on power loss?
The cited manual describes emergency breakout as an option. Confirm the actual mechanical arrangement, locks, modes, power and project interface requirements; the model name does not settle all emergency states.
Can reception change the mode without a direct view of the door?
The cited manual's section 4.17 limits reception-panel roles according to line of sight. The relevant no-direct-view arrangement is read-only. Confirm the actual equipment layout and permitted function rather than assuming that a display provides control.
Should a door that will not rotate receive a reset or replacement board first?
Preserve the full identity, mode, indication, behaviour and recent changes, then arrange investigation under the applicable documents. Do not diagnose a failed part from one symptom or repeatedly run the door to overcome a fault.